<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>16019</ErrorNumber>
<ErrorFamily>Image</ErrorFamily>
<ErrorMessage>
IMAGE: exposure too high
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Green</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Based on the maximum light level recorded in the DAOM calibration table, the head will not be able to
achieve the requested exposure level.  The exposure head may be failing, or the DAOM calibration stored
in NVS is for another head.
</text></DescriptionText>
<DescriptionText><text>
At any rate, a "daom cal" (and "nvs save daom") should be performed.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Lower the exposure level if possible.  Contact Creo Service because the Platesetter may need servicing.
</text></DescriptionText>
</OperatorAction>
<Cause>
Exposure level unreasonably high
</Cause>
<Cause>
DAOM calibration not performed for new head
</Cause>
<Cause>
Head is failing - perform new DAOM calibration
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../commands/daom.xml</LinkAddress><LinkTitle>Command: daom</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:28 2008 PST
</Updated>
<Links>
</Links>
</Error>